Lamps needed for 1983 time machine zaccaria pinball machine
(There is nothing special about the resistance value. This causes a voltage drop in the machine when the current spikes occur.
LAMPS NEEDED FOR 1983 TIME MACHINE ZACCARIA PINBALL MACHINE SERIES
In the case of this repair job, I installed a 2 ohm, 50 watt resistor in series with the line, downstream from the fuse, to help limit the current spikes. Try to filter the pinball power so that the arcs and current spikes are not as noticeable to the breaker.But, some brands are apparently less prone to nuisance tripping. This is not as easy as it sounds since certain brands can only work in a certain panels.
Using some specialized equipment, I measured very short current spikes of over 15 amps on the line cord when all 4 flippers engaged simultaneously along with a pop bumper or target bank reset coil. The breaker only tripped when playing, which is when the arcs in the switch contacts are being generated. If tripped without playing, it would have indicated an unsafe condition. Besides, having the pinball machine turned on and left on, without playing, didn’t trip the breaker. I carefully checked this pinball machine for any unsafe condition such as a bad line cord, ungrounded line cord, bad connections, etc., and could find nothing. An electromechanical pinball machine has over a hundred switch contacts and many dozens of coils, which combine to create arcs at the switch contacts. I’m sure the designers of arc-fault circuit interrupters didn’t design them with an old pinball machine in mind. However, the arcs caused in an electro-mechanical pinball machine are totally random, based on flipper usage and what the ball is doing at any given moment.
In the case of an electrical motor, the arcs occur at regular intervals and the AFCI can be designed to ignore these. Therefore the arc fault breakers are supposed to be able to tell the difference between a safe arc and an unsafe arc, but sometimes they don’t do a very good job. These devices have naturally occurring sparks being generated internally. The problem is many devices cause nuisance (false) tripping, such as pinball machines and brush type motors used in vacuum cleaners and drills. The house was recently constructed and has arc-fault (AFCI) circuit breakers installed on most circuits, which is now required by code.Īrc fault breakers are designed to detect arcing conditions in the electrical circuits of a house which could cause a fire.